| Code postal: |
|
|
| Nom: |
1 Ch, Load Cell / Strain Gauge Bridge Isolating Repeater |
|
| Type: |
|
|
| Alimentation: |
20-30 Vdc |
|
| Instrument de site: |
|
|
| Voies: |
1 |
|
| Description: |
The D1063S acts as transparent and very accurate galvanic isolated interface installed between a weighing indicator/system in Safe Area and a load cell (or group of load cells) in Hazardous Location. The output to the indicator/system is a transparent reflection of a single load cell equivalent to the one/s in the field. The unit provides a fully floating power supply voltage with remote sensing capability to the strain gauge bridge/s located in Hazardous Location and repeats, with isolation, the mV signal output to drive the load in Safe Area dependent from the host system reference voltage. Up to four 350 Ohm load cells, or six 400 Ohm load cells, or twelve 1.000 Ohm load cells can be connected in parallel. The Safe Area side voltage reference is configurable as internal or as external (host system) supply.
In addition a field wiring fault LED indicates any lead break in the Hazardous Location side. Approved for Div. 2 installation. |
|
| Zone Dangereuse: |
Up to four 6 wire paralleled load cells 350 Ohm, 5 V, 80 mA total capacity. |
|
| Zone Non Dangereuse: |
mV corrisponding to Input Bridge. Accuracy, after system calibration: 0,003 %. |
|
| Fonction: |
1 channel I.S. input from strain gauge signals, provides 3 port isolation
(input/output/supply) and repeats, as a transparent unit, bridge signal output. |
|
| Caractéristiques: |
Completely transparent to weighing system
0,003 % Accuracy.
No need of safety ground.
Up to four 350 Ohm Load cell input.
Multi-drop connection for up to 16 Load cell inputs. |
|
| Feuille de données: |
 | DTS0185 | D1063S Feuille de données (English) (PDF 258 KB) |
 |
 | DTS0309 | D1063S Feuille de données (Italiano) (PDF 257 KB) |
 |
 | DTS0220 | D1063S Feuille de données (Pусский) (PDF 286 KB) |
 |
|
|
| Manuel d'instruction: |
 | ISM0069 | D1063S manuel d'instruction (PDF 540 KB) |  |  | ISM0102 | General D1000 Series Instruction Manual (PDF 2.39 MB) |  | |
|
| Certifications: |
 | CRT007 | ATEX DNV 0199 (PDF 2.85 MB) |
 |
 | CRT010 | Rostehnadzor for D1000 and T3010 Series (Russia) (PDF 730 KB) |
 |
 | CRT011 | Gost R Certificate for D1000 Series (Russia) (PDF 2.00 MB) |
 |
 | CRT014 | Metrological Certificate for D1000 Series (Russia) (PDF 202 KB) |
 |
 | CRT020 | FM 3024643 (USA) & FM-C 3029921C (Canada) (PDF 3.42 MB) |
 |
 | CRT023 | DNV Certificate for Ships and Offshore Standards (PDF 1.03 MB) |
 |
 | CRT028 | Korean Register Type Approval Certificate (PDF 577 KB) |
 |
 | CRT033 | IECEx Certificate for D1000 Series (PDF 88 KB) |
 |
 | CRT047 | ATEX Certificate D1000 Series by IMQ (PDF 1.02 MB) |
 |
 | CRT053 | TCCExEE Expert report for D1000 Series (Ukraine) (PDF 3.05 MB) |
 |
|
|
| Notes d'applications: |
 | APN0007 | Universal AC Power Supply for Series D1000 (PDF 44 KB) |  | |
|
| Accessoires: |
| BUS | Power Bus Optional Enclosure | | CABF012 | Dedicated cable for load cell 3x2x1 mm2 with 3+overall screen | |
|
| Diverses: |
|
|
| Nouveautés: |
[Documents] New Company and Products Catalog
[Certifications and Reports] IECEx Certifications for D1000 Series now available
[Certifications and Reports] D1000 Series DNV Certificate for Ships and Offshore
[Products] D1063S Load cells isolator certification available
|
|
|